R&S FSL WLAN TX Measurements (Option K91 / K91n)
1300.2519.12 4.437 E-11
Meas Single/Cont
Selects the sweep mode.
Single
single sweep mode
Cont
continuous sweep mode
Remote: INIT:CONT OFF (single sweep mode)
Remote: INIT:CONT ON (continuous sweep mode)
Auto Level
Starts an automatic level detection measurement. If this softkey is pressed while a measurement
is running, the current measurement is aborted and the automatic level detection measurement
is started. If the aborted measurement was a continuous measurement it is resumed after the
automatic level detection is completed.
Remote: CONF:POW:AUTO ON
Refresh
Updates the current measurement results with respect to the current gate settings. This softkey
is only available if the measurement results are effected by the gate settings (Spectrum FFT,
PVT and CCDF) and if the gate settings are modified after a measurement result has been
obtained.
Softkeys of the marker menu (WLAN mode)
The following table shows all softkeys available in the marker menu in WLAN mode (MKR key). It is
possible that your instrument configuration does not provide all softkeys. If a softkey is only available
with a special option, model or (measurement) mode, this information is delivered in the corresponding
softkey description. Close all settings dialog boxes before opening the marker menu.
Command
Marker 1
Unzoom
Marker Zoom
Marker Off
Marker 1
Opens a dialog box to adjust the marker. The contents of the dialog box depends on the type of
graph the marker is adjusted to. After every change, the marker position in the trace and the
marker information are updated.
Remote: CALC:MARK ON
Remote: CALC:MARK:X 2ms
Remote: CALC2:MARK:Y –2
Remote: CALC:MARK:SYMB 2
Remote: CALC:MARK:CARR –7