1300.2519.12 4.454 E-11
Signal Level (General Settings dialog box)
Specifies the expected level of the RF input signal. If an automatic level detection measurement
has been executed, the signal level (RF) is updated.
Remote: CONF:POW:EXP:RF –20
Auto Lev (General Settings dialog box)
Activates or deactivates the automatic setting of the reference level for measurements.
On The reference level is measured automatically at the start of each measurement
sweep. This ensures that the reference level is always set at the optimal level for
obtaining accurate results but will result in slightly increased measurement times. For
details about level detection refer to chapter "Advanced Measurement Examples".
Off
The reference level is defined manually in the Signal Level field.
Remote: CONF:POW:AUTO ON
Remote: CONF:POW:AUTO:SWE:TIME 200MS
Ext Att (General Settings dialog box)
Specifies the external attenuation or gain applied to the RF signal. A positive value indicates
attenuation, a negative value indicates gain. All displayed power level values are shifted by this
value.
Remote: DISP:TRAC:Y:RLEV:OFFS 10
Capture Time (General Settings dialog box)
Specifies the time (and therefore the amount of data) to be captured in a single measurement
sweep.
Remote: SWE:TIME 10ms
Burst Count (General Settings dialog box)
Activates or deactivates a specified number of bursts for capture and analysis.
On The data analysis is performed over a number of consecutive sweeps until the
required number of bursts has been captured and analyzed.
Off The data analysis is performed on a single measurement sweep.
Remote: BURS:COUN:STAT ON
Analyze Bursts (General Settings dialog box)
Specifies the number of bursts to be measured, if the Burst Count option is activated.
If the number of bursts of the specified type is not contained in a single measurement sweep,
the measurement sweeps continue until the requested number of bursts have been captured.