R&S FSL WiMAX, WiBro Measurements (Options K92/K93)
1300.2519.12 4.459 E-11
Max Data Symbols (Demod Settings dialog box, IEEE 802.16–2004 OFDM)
Specifies the maximum number of data symbols that a burst must have to be considered in
measurement analysis. This field is only available if the Equal Burst Length option is
deactivated.
Remote: DEM:FORM:BAN:SYMB:MAX 1300
Channel Estimation (Demod Settings dialog box, IEEE 802.16–2004 OFDM)
Specifies how accurately the EVM results are calculated.
Preamble
The channel estimation is performed in the preamble as required in the
standard.
Payload
The channel estimation is performed in the payload.
Remote: DEM:CEST ON
Phase (Demod Settings dialog box)
Activates or deactivates the compensation for the phase error. If activated, the measurement
results are compensated for phase error on a per–symbol basis.
Remote: TRAC:PHAS ON
Timing (Demod Settings dialog box)
Activates or deactivates the compensation for the timing error. If activated, the measurement
results are compensated for timing error on a per–symbol basis.
Remote: TRAC:TIME ON
Level (Demod Settings dialog box, IEEE 802.16–2004 OFDM)
Activates or deactivates the compensation for the level error. If activated, the measurement
results are compensated for level error on a per–symbol basis.
Remote: TRAC:LEV ON
Downlink (DL) (Demod Settings dialog box, IEEE 802.16e–2005 OFDMA/WiBro)
Specifies how channel estimation is performed for downlink signals.
Preamble Only
The channel estimation is performed in the preamble only.
Preamble and Payload
The channel estimation is performed in the preamble and in the
payload (payload comprises pilots and data).
Payload Only
The channel estimation is performed in the payload only.
Remote: DEM:CEST PREAMPAYL