Remote Control Commands
R&S
®
SMW200A
1002User Manual 1175.6632.02 ─ 30
Example:
SOURce1:BB:DM:FORMat APSK32
SOURce1:BB:DM:APSK32:GAMMa G9D10
Manual operation: See "Gamma/Gamma 1" on page 274
[:SOURce<hw>]:BB:DM:SWITching:STATe <State>
Enables switching between a modulated and an unmodulated signal.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
SCONfiguration:MODE ADV
SCONfiguration:APPLy
SOURce1:BB:DM:SWITching:STATe ON
Manual operation: See "State Modulation CW Switching" on page 274
Power Ramping
[:SOURce<hw>]:BB:DM:PRAMp:SOURce <Source>
Sets the source for the power ramp control signals.
Parameters:
<Source> INTernal
*RST: INTernal
Example: See Example "Enable power ramping" on page 991
Options: R&S SMW-B10
Manual operation: See "Source" on page 277
[:SOURce<hw>]:BB:DM:PRAMp:SHAPe <Shape>
Sets the edge shape of the ramp envelope.
Parameters:
<Shape> LINear | COSine
*RST: COSine
Example: See Example "Enable power ramping" on page 991
Options: R&S SMW-B10
Manual operation: See "Ramp Function" on page 278
[:SOURce<hw>]:BB:DM:PRAMp:TIME <Time>
Sets the power ramping rise time and fall time for a burst.
SOURce Subsystem