Remote Control Commands
R&S
®
SMW200A
1006User Manual 1175.6632.02 ─ 30
Example:
SOURce1:BB:DM:TRIGger:SOURce ELTRigger
SOURce1:BB:DM:TRIGger:SEQuence ARETrigger
SOURce1:BB:DM:TRIGger:RMODe?
Response: RUN
Usage: Query only
Manual operation: See "Running/Stopped" on page 253
[:SOURce<hw>]:BB:DM:TRIGger:EXTernal:SYNChronize:OUTPut <Output>
Enables signal output synchronous to the trigger event.
Parameters:
<Output> 0 | 1 | OFF | ON
*RST: 1
Example: See Example "Adjusting clock, marker and trigger settings"
on page 990
Manual operation: See "Sync. Output to External Trigger/Sync. Output to Trigger"
on page 254
[:SOURce<hw>]:BB:DM:TRIGger:ARM:EXECute
Stops signal generation; a subsequent internal or external trigger event restart signal
generation.
Example:
See also Example "Adjusting clock, marker and trigger settings"
on page 990
Usage: Event
Manual operation: See "Arm" on page 253
[:SOURce<hw>]:BB:DM:TRIGger:EXECute
Executes a trigger.
Example:
See Example "Adjusting clock, marker and trigger settings"
on page 990
Usage: Event
Manual operation: See "Execute Trigger" on page 254
[:SOURce<hw>]:BB:DM:TRIGger:OBASeband:DELay <Delay>
Specifies the trigger delay (expressed as a number of symbols) for triggering by the
trigger signal from the other path.
SOURce Subsystem