1008User Manual 1175.6632.02 ─ 30
Parameters:
<Inhibit> integer
Range: 0 to 67108863
*RST: 0
Default unit: symbol
Example: See Example "Adjusting clock, marker and trigger settings"
on page 990
Manual operation: See "External / Trigger Inhibit" on page 255
[:SOURce<hw>]:BB:DM:TRIGger:DELay:UNIT
<TrigDelUnit>
Determines the units the trigger delay is expressed in.
Parameters:
<TrigDelUnit> SAMPle | TIME
*RST: SAMPle
Example: See Example "Specifying delay and inhibit values in time units"
on page 1022
Manual operation: See "(External) Delay Unit" on page 255
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal]:DELay <Delay>
Specifies the trigger delay in symbols.
Maximum trigger delay and trigger inhibit values depend on the installed options. See
"Specifying delay and inhibit values" on page 242.
Parameters:
<Delay> float
Range: 0 to depends on the symbol rate
Increment: 0.01
*RST: 0
Default unit: symbol
E.g. 0 to 2147483647 symbols (R&S SMW-B10)
Example: See Example "Adjusting clock, marker and trigger settings"
on page 990.
Manual operation: See "(Specified) External Delay/(Specified) Trigger Delay"
on page 255
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal]:TDELay <ExtTimeDelay>
Specifies the trigger delay for external triggering. The value affects all external trigger
signals.
Maximum trigger delay and trigger inhibit values depend on the installed options. See
"Specifying delay and inhibit values" on page 242.