Remote Control Commands
R&S
®
SMW200A
1087User Manual 1175.6632.02 ─ 30
<BitCount> integer
0 = marker off, 1 = marker on
Range: 1 to 64
*RST: 2
Example: See "Programming Examples" on page 1071.
Manual operation: See "Marker Mode" on page 257
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PULSe:DIVider <Divider>
Sets the divider for pulse marker mode.
*)
If R&S SMW-B9 is installed, the minimum marker duration depends on the sample/
symbol rate.
See "Marker Minimum Duration" on page 234.
Parameters:
<Divider> integer
Range: 2 (R&S SMW-B10) / 2* (R&S SMW-B9) to 1024
*RST: 2
Example: See "Programming Examples" on page 1071
Manual operation: See "Marker Mode" on page 257
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PULSe:FREQuency?
Queries the pulse frequency of the pulsed marker signal.
Return values:
<Frequency> float
Increment: 1E-3
Example: see "Programming Examples" on page 1071
Usage: Query only
Manual operation: See "Marker Mode" on page 257
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:DELay <Delay>
Defines the delay between the signal on the marker outputs and the start of the sig-
nals, expressed as number of samples.
Parameters:
<Delay> float
Range: 0 to 16777215
Increment: 0.001
*RST: 0
Example: See "Programming Examples" on page 1071.
SOURce Subsystem