Remote Control Commands
R&S
®
SMW200A
1105User Manual 1175.6632.02 ─ 30
Manual operation: See "Remove" on page 608
[:SOURce]:BB:GRAPhics:ADD <Size>
Adds a graphical signal display (according to the current MODE, SOURce, SRATe:* and
TRIGger:* settings).
Setting parameters:
<Size> MAXimized | MINimized
Usage: Setting only
Manual operation: See "Add" on page 608
[:SOURce]:BB:GRAPhics:SOURce <Source>
Defines the signal acquisition point, that is the location in the signal flow where the dis-
played signal is tapped from.
The available acquisition points depend on the selected system configuration.
Parameters:
<Source> STRA | STRB | STRC | STRD | STRE | STRF | STRG | STRH |
BBA | BBB | BBC | BBD | BBE | BBF | BBG | BBH | RFA | RFB |
RFC | RFD | IQO1 | IQO2 | DO1 | DO2 | BBIA | BBIB
STRA|STRB|STRC|STRD|STRE|STRF|STRG|STRH
Streams (A to H); input stream of the "IQ Stream Mapper"
BBA|BBB|BBC|BBD|BBE|BBF|BBG|BBH
Baseband signals (A to H)
BBIA|BBIB
Digital baseband input signals
RFA|RFB|RFC|RFD
RF signals (A to D)
IQO1|IQO2
Analog I/Q output signals
DO1|DO2
Digital I/Q output signals; outputs of the "IQ Stream Mapper"
*RST:
STRA
Manual operation: See "Source" on page 606
Location and use of the source types is shown in Chapter 9.1.2.2, "Signal Acquisition
Points", on page 602.
[:SOURce]:BB:GRAPhics:SOURce:MUX <Mode>
In :SCONfiguration:OUTPut:MODE DIGMux mode, select which of the multiplexed
streams is displayed.
SOURce Subsystem