Remote Control Commands
R&S
®
SMW200A
1124User Manual 1175.6632.02 ─ 30
Example: See Example "Enabling high-quality optimization" on page 1122.
Usage: Event
14.19.6 SOURce:FREQuency Subsystem
The SOURce:FREQuency subsystem contains the commands used to define the fre-
quency settings for the RF sources and sweeps.
Example: Frequency configuration
SOURce1:FREQuency:MODE CW
SOURce1:FREQuency:CW 6000000000
SOURce1:FREQuency:OFFSet 2000000000
SOURce1:FREQuency:MULTiplier 1.5
SOURce1:FREQuency:CW?
// 11000000000
// SOURce1:FREQuency:STEP:MODE USER
// SOURce1:FREQuency:STEP:INCRement 1000000
// SOURce1:FREQuency:CW UP
SOURce1:PHASe 2
SOURce1:PHASe:REFerence
Example: Set up of LO coupling and LO level adjustment with three
Rohde & Schwarz signal generators
This example shows the command sequences for coupling the oscillator signal of three
signal generators connected according to the setup on Figure 14-6.
Connect the instruments in a daisy-chain regarding the LO signal:
Connect the LO OUT of the first generator with LO IN of the second
Connect the LO OUT of the second generator with LO IN of the third.
The frequency is assumed to be 5 GHz.
Figure 14-6: Set up of LO coupling with three Rohde
&
Schwarz signal generators
Signal generator#1 = One-path instrument, uses its internal oscillator signal.
Signal generator#1 = Two-paths instrument; receives the LO signal from the first instrument and assigns it to
both paths
Signal generator#3 = One-path instrument; receives the LO signal from the second instrument