Remote Control Commands
R&S
®
SMW200A
1131User Manual 1175.6632.02 ─ 30
Manual operation: See "Multiplier" on page 463
[:SOURce<hw>]:FREQuency:OFFSet <Offset>
Sets the frequency offset f
FREQ:OFFSet
of a downstream instrument.
The parameters offset f
FREQ:OFFSer
and multiplier N
FREQ:MULT
affect the frequency value
set with the command FREQ.
The query FREQ? returns the value corresponding to the formula:
f
FREQ
= f
RFout
* N
FREQ:MULT
+ f
FREQ:OFFSer
See Chapter 8.4.4.1, "Displayed RF Frequency and Level Values with Downstream
Instruments", on page 472.
Note: The offset also affects RF frequency sweep.
Parameters:
<Offset> float
Increment: 0.01
*RST: 0
Example: See Example "Frequency configuration" on page 1124
Manual operation: See "Offset" on page 463
[:SOURce<hw>]:FREQuency:CENTer <Center>
Sets the center frequency of the sweep.
See Chapter 8.7.2.1, "Correlating Parameters in Sweep Mode", on page 501.
Parameters:
<Center> float
Range: 300 kHz to RFmax
Increment: 0.01 Hz
*RST: 300E6
Default unit: Hz
Example: See Example "Setup an RF frequency or power sweep"
on page 1206
Manual operation: See "Center Frequency" on page 514
[:SOURce<hw>]:FREQuency:SPAN <Span>
Sets the sapn of the frequency sweep range.
See Chapter 8.7.2.1, "Correlating Parameters in Sweep Mode", on page 501.
SOURce Subsystem