Remote Control Commands
R&S
®
SMW200A
1146User Manual 1175.6632.02 ─ 30
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:SRATe:SUM?.................................................1152
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:SRATe:MAX?................................................. 1152
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:STATe <State>
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:STATe <State>
Activates the digital I/Q signal output.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
SOURce:IQ:OUTPut:DIGital:BBMM2:STATe ON
Activates the [BBMM 2] output connector.
Manual operation: See "State" on page 176
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:SLOW:STATe <SlowIqState>
Enables/disables slow IQ mode.
See user manual R&S SMW-K551 Generation of Digital "Slow IQ" Signals.
Parameters:
<SlowIqState> 0 | 1 | OFF | ON
*RST: 0
Options: R&S SMW-K551
Manual operation: See "Slow IQ State" on page 176
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:PON <Pon>
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:PON <Pon>
Sets the power-on state of the selected digital I/Q output.
Parameters:
<Pon> OFF | UNCHanged
*RST: UNCHanged
Example:
:SOURce:IQ:OUTPut:DIGital:BBMM2:PON OFF
Deactivates the [BBMM 2] output connector when the instrument
is switched on.
Manual operation: See "Power-On State" on page 181
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:SRATe:SOURce <Source>
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:SRATe:SOURce <Source>
Selects whether the sample rate is estimated based on the digital signal or is a user-
defined value.