Remote Control Commands
R&S
®
SMW200A
1172User Manual 1175.6632.02 ─ 30
[:SOURce<hw>]:LIST:RMODe <RMode>
Selects the run mode for processing the list.
Parameters:
<RMode> LEARned | LIVE
LEARned
Generates the signal by replaying the previously learned and
saved data from the temporary memory.
LIVE
Generates the signal by processing the list directly.
*RST: LIVE
Example: See Example "Create an RF list and activate the list mode"
on page 1165.
Manual operation: See "Run Mode" on page 520
[:SOURce<hw>]:LIST:LEARn
Learns the selected list to determine the hardware setting for all list entries. The results
are saved with the list.
See also "Learn List Mode Data list processing mode" on page 507.
Example:
See Example "Create an RF list and activate the list mode"
on page 1165.
Usage: Event
Manual operation: See "Learn List Mode Data" on page 520
[:SOURce<hw>]:LIST:MODE <Mode>
Sets the list mode.
The instrument processes the list according to the selected mode and trigger source.
See LIST:TRIG:SOUR AUTO, SING or EXT for the description of the trigger
source settings.
Parameters:
<Mode> AUTO | STEP
AUTO
Each trigger event triggers a complete list cycle.
STEP
Each trigger event triggers only one step in the list processing
cycle. The list is processed in ascending order.
*RST: AUTO
Example: See Example "Create an RF list and activate the list mode"
on page 1165.
Manual operation: See "Mode" on page 519
SOURce Subsystem