Remote Control Commands
R&S
®
SMW200A
1174User Manual 1175.6632.02 ─ 30
The designation of the parameters correspond to those in sweep mode. SCPI standard
uses other designations for the parameters, which are also accepted by the instrument.
The SCPI designation should be used if compatibility is an important consideration. For
an overview, see the following table:
Rohde & Schwarz parameter SCPI parameter Applies to the list mode parameters:
AUTO IMMediate [:SOURce<hw>]:LIST:MODE AUTO
SINGle BUS
[:SOURce<hw>]:LIST:MODE AUTO or
[:SOURce<hw>]:LIST:MODE STEP
EXTernal EXTernal
[:SOURce<hw>]:LIST:MODE AUTO or
[:SOURce<hw>]:LIST:MODE STEP
Parameters:
<Source> AUTO | IMMediate | SINGle | BUS | EXTernal
AUTO|IMMediate
The trigger is free-running, i.e. the trigger condition is fulfilled
continuously. The selected list is restarted as soon as it is fin-
ished.
SINGle|BUS
The list is triggered by the command [:SOURce<hw>]:LIST:
TRIGger:EXECute. The list is executed once.
EXTernal
The list is triggered externally and executed once.
*RST: AUTO
Example: See Example "Create an RF list and activate the list mode"
on page 1165.
Manual operation: See "Mode" on page 519
[:SOURce<hw>]:LIST:RUNNing?
Queries the current state of the list mode.
Return values:
<State> 0 | 1 | OFF | ON
1
Signal generation based on the list mode is active.
Example: See Example "Create an RF list and activate the list mode"
on page 1165.
Usage: Query only
14.19.12.2 List Mode File Operation
The following section covers basic commands to file handling in list mode.