Remote Control Commands
R&S
®
SMW200A
1186User Manual 1175.6632.02 ─ 30
14.19.14 SOURce:PGEN Subsystem
The PGEN subsystem contains the commands for setting output of the pulse modula-
tion signal.
Example: Using pulse generator as source for pulse modulation
// select pulse generator as source for pulse modulation
// enable pulse modulation
SOURce1:PULM:SOURce INT
SOURce1:PULM:STATe 1
// pulse generator and signal output are also activated
SOURce1:PGENerator:STATe?
// 1
SOURce1:PGENerator:OUTPut:STATe?
// 1
PGENerator:OUTPut:POLarity NORMal
// to disable pulse generator
SOURce1:PGENerator:STATe 0
// activate the pulse modulation of the RF carrier
SOURce1:PULM:STATe 1
[:SOURce<hw>]:PGENerator:OUTPut:POLarity.............................................................. 1186
[:SOURce<hw>]:PGENerator:OUTPut[:STATe]................................................................ 1186
[:SOURce<hw>]:PGENerator:STATe.............................................................................. 1187
[:SOURce<hw>]:PGENerator:OUTPut:POLarity <Polarity>
Sets the polarity of the pulse output signal.
Parameters:
<Polarity> NORMal | INVerted
NORMal
Outputs the pulse signal during the pulse width, that means dur-
ing the high state.
INVerted
Inverts the pulse output signal polarity. The pulse output signal is
suppressed during the pulse width, but provided during the low
state.
*RST: NORMal
Example: See Example "Using pulse generator as source for pulse modu-
lation" on page 1186.
Manual operation: See "Pulse Output Polarity" on page 551
[:SOURce<hw>]:PGENerator:OUTPut[:STATe] <State>
Activates the output of the pulse modulation signal.
SOURce Subsystem