EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - Source:phase Subsystem

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMW200A
1187User Manual 1175.6632.02 ─ 30
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Using pulse generator as source for pulse modu-
lation" on page 1186.
Manual operation: See "Pulse Output State" on page 551
[:SOURce<hw>]:PGENerator:STATe <State>
Enables the output of the video/sync signal.
If the pulse generator is the current modulation source, activating the pulse modulation
automatically activates the signal output and the pulse generator.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Using pulse generator as source for pulse modu-
lation" on page 1186.
14.19.15 SOURce:PHASe Subsystem
This subsystem contains the commands for adjusting the phase of the RF output signal
relative to a reference signal of the same frequency.
Example: Programming Example
// change the phase relative to the current phase
SOURce1:PHASe 2 DEG
// adopt the setting as the current phase
SOURce1:PHASe:REFerence
The following commands are available:
[:SOURce<hw>]:PHASe................................................................................................1187
[:SOURce<hw>]:PHASe:REFerence.............................................................................. 1188
[:SOURce<hw>]:PHASe <Phase>
Sets the phase variation relative to the current phase.
Parameters:
<Phase> float
Range: -720 to 720
Increment: 0.1
*RST: 0
Default unit: DEG
Example: See Example "Programming Example" on page 1187.
SOURce Subsystem