Remote Control Commands
R&S
®
SMW200A
1204User Manual 1175.6632.02 ─ 30
Usage: Query only
Manual operation: See "Calibrated Level (PEP)" on page 659
:SOURce<hw>:RFALignment:FOFFset?
Queries the applied baseband frequency offset.
Return values:
<BbFreqOffset> float
Increment: 0.01
Example: See Example "Retrieving details on the calibrated values"
on page 935.
Usage: Query only
Manual operation: See "Baseband Frequency Offset" on page 660
:SOURce<hw>:RFALignment:DATTenuation?
Queries the applied digital attenuation.
Return values:
<Attenuation> float
Increment: 0.01
Example: See Example "Retrieving details on the calibrated values"
on page 935.
Usage: Query only
Manual operation: See "Digital Attenuation" on page 660
:SOURce<hw>:RFALignment:CORRection:PHASe?
queries the delta phase applied for compensation of the frequency response of the sig-
nal.
Return values:
<Phase> float
Increment: 0.01
Example: See Example "Retrieving details on the calibrated values"
on page 935.
Usage: Query only
Manual operation: See "Phase" on page 660
:SOURce<hw>:RFALignment:CORRection:LEVel?
Queries the level correction applied to the signal of the selected path.
SOURce Subsystem