Signal Routing and System Configuration
R&S
®
SMW200A
127User Manual 1175.6632.02 ─ 30
"GNSS
Advanced"
Option: R&S SMW-K120
Transforms the R&S SMW to a GNSS simulator.
The fading simulator is disabled.
See user manual R&S®SMW Satellite Navigation.
"Extended
Sequencer
Advanced"
Option: R&S SMW-B15/-K315
Enables the R&S SMW to work in an advanced extended sequencer
mode.
The fading simulator, the AWGN, the BB input and all baseband digi-
tal standards are disabled.
See user manual R&S®SMW-K501/-K502/-K503/-K504/-K315 Exten-
ded and Real-Time Sequencing, Real-Time Control Interface, Exten-
ded Pulse Rate, Permanent Emitters.
Remote command:
:SCONfiguration:MODE on page 914
Signal Outputs
Defines whether an analog and digital or digital only signal is generated.
The keyword (HS) indicates that the signal is routed to the HS DIG I/Q connectors. If
this keyword is missing, the signal is routed to the DIG I/Q connectors.
Baseband gener-
ator
Mode Signal Out-
puts
Description Options
R&S SMW-B10 Standard
Advanced
"Analog&Digi-
tal"
The instrument generates signals with high data rate.
Generated streams can be mapped to the analog connectors
and to the DIG I/Q interfaces.
Advanced "Digital Only" Baseband signal can only be output as digital signal at the
DIG I/Q interfaces. The baseband signal cannot be routed to
the RF and I/Q analog output.
Analog signal generation is possible with external analog I/Q
signals. Alternatively, you can generate continuous wave sig-
nals, analog modulated signals or RF signals in sweep or list
mode.
R&S SMW-
K18
Advanced "Digital Only
Multiplexed"
R&S SMW can process up to 4 multiplexed streams received
over the same connector.
With options R&S SMW-B10 and R&S SMW-K551, the
R&S SMW can also generate digital signals with reduced
speed, depending on the device connected to the digital I/Q
interfaces. The multiplexed streams are then mapped to the
digital I/Q interfaces BBMM 1/2; the mapping is fixed.
R&S SMW-
K18
R&S SMW-B9 Standard "Analog Only" Disables the digital outputs.
"Digital Only
(HS)"
Works like "Digital Only" in Standard baseband but the base-
band signal is output at the HS DIG I/Q interface.
R&S SMW-
K19
Advanced "Analog&Digi-
tal"
Generated streams can be mapped to the analog connectors
and to the DIG I/Q interfaces.
"Digital Only
(HS)"
Works like "Digital Only" in Standard baseband but the base-
band signal is output at the HS DIG I/Q interface.
R&S SMW-
K19
"Analog&Digi-
tal (HS)"
Generated streams can be mapped to the analog connectors
and to the HS DIG I/Q interfaces.
R&S SMW-
K19
System Configuration Settings