Signal Routing and System Configuration
R&S
®
SMW200A
139User Manual 1175.6632.02 ─ 30
The dialog lists the connectors, required for the current "Fading and Baseband Config-
uration".
See also:
Chapter 4.3.1, "Physical Location of the Input and Output Interfaces", on page 114
Chapter 4.4.1, "Fading and Baseband Configuration Settings", on page 125
Chapter 4.3.4, "Supported Digital Interfaces Depending on the System Configura-
tion", on page 119
Remote command:
via keyword in the SCPI syntax, e.g. IQOutput
Direction
Displays the connector direction as a color coded field.
Where:
The direction is determined by the selected "Fading and Baseband Configuration".
The color is determined by the configuration in the "I/Q Stream Mapping" dialog.
The following table gives an overview of the possible combinations and explains the
used designations.
Connector Direction/
Color
Enabled in the "Fading and Base-
band Configuration"
Enabled in the "I/Q
Stream Mapping"
CODER Yes -
Input
Gray
Not used -
FADER Yes -
Yes Yes
Yes Not used
Not used Not used
BBMM Yes Yes
Yes Not used
System Configuration Settings