Signal Routing and System Configuration
R&S
®
SMW200A
141User Manual 1175.6632.02 ─ 30
Indication Designation
green LED and an icon
The DIG I/Q/HS DIG I/Q interface is used as an input connector
yellow LED and an icon
The DIG I/Q/HS DIG I/Q interface is used as an output connector
icon without an LED
An external instrument is connected to the DIG I/Q interface, but no direction
is specified
No icon displayed No connection
"Single Ended"/"Differen-
tial"
Selects the type of the I/Q output signal at the I/Q output connector
Works like the parameter "I/Q Output Type" on page 147.
Remote command:
:SCONfiguration:EXTernal:CODer<ch>:IQConnection:STATe? on page 926
:SCONfiguration:EXTernal:FADer<ch>:IQConnection:STATe? on page 926
:SCONfiguration:EXTernal:BBMM<ch>:IQConnection:STATe? on page 926
Remote Connection Status
Indicates the status of the remote connection. Click the status indicator to toggle the
remote connection status.
To connect/disconnect all external instruments, use the functions Connect/Disconnect
All Remote.
Note:
External instruments connected to the R&S SMW are preset (:DEVice:PRESet)
whenever:
●
The connection to the external instrument is established or terminated ("Connect/
Disconnect All Remote" or "Rem. Conn > On/Off")
●
The R&S SMW is preset ([PRESET]).
Note: An active "Rem. Conn." and an "RF State > On" do not mean that an I/Q stream
is mapped to this connector.
Use the "System Configuration > External Rf and I/Q > Display > Mapped Connectors"
filter to list only the connectors with a mapped I/Q stream.
Remote command:
:SCONfiguration:EXTernal:CODer<ch>:RCONnection:STATe? on page 926
:SCONfiguration:EXTernal:CODer<ch>:REMote:DISConnect on page 933
:SCONfiguration:EXTernal:CODer<ch>:REMote:INFO? on page 932
:SCONfiguration:EXTernal:FADer<ch>:RCONnection:STATe? on page 926
:SCONfiguration:EXTernal:FADer<ch>:REMote:DISConnect on page 933
:SCONfiguration:EXTernal:FADer<ch>:REMote:INFO? on page 932
:SCONfiguration:EXTernal:BBMM<ch>:RCONnection:STATe? on page 926
:SCONfiguration:EXTernal:BBMM<ch>:REMote:DISConnect on page 933
:SCONfiguration:EXTernal:BBMM<ch>:REMote:INFO? on page 932
:SCONfiguration:EXTernal:IQOutput<ch>:RCONnection:STATe?
on page 926
:SCONfiguration:EXTernal:IQOutput<ch>:REMote:DISConnect
on page 933
:SCONfiguration:EXTernal:IQOutput<ch>:REMote:INFO? on page 932
:SCONfiguration:EXTernal:RF<ch>:RCONnection:STATe? on page 926
System Configuration Settings