Signal Routing and System Configuration
R&S
®
SMW200A
148User Manual 1175.6632.02 ─ 30
Initialization Sequence
Accesses the standard "File Select" dialog for loading an existing initialization file
(extension *.iec).
When you establish the connection to an external instrument, i.e. Remote Connection
Status is active, the R&S SMW performs the following:
Sends the command :DEVice:PRESet
Sends the content of the initialization sequence file to reconfigure the external
instrument
If necessary, perform further settings and configuration of the external instruments.
Tip: Try out also the following:
Send individual SCPI commands or a sequence of SCPI commands to the connec-
ted instruments or define your own initialization sequence and load the file
See "To create a remote control sequence or modify the initialization sequence"
on page 203
If you are configuring the R&S SMW remotely from a controller, try out to remote
control the connected R&S SGS/R&S SGT via the R&S SMW.
See:
Example "Controlling the R&S SMW and external RF instruments with the
same application program" on page 908
Example "Connecting an external instrument and sending SCPI commands to
it" on page 911
Remote command:
:SCONfiguration:EXTernal:REMote:INITialization:CATalog?
on page 933
:SCONfiguration:EXTernal:CODer<ch>:REMote:INITialization:FILE
on page 933
:SCONfiguration:EXTernal:FADer<ch>:REMote:INITialization:FILE
on page 933
:SCONfiguration:EXTernal:BBMM<ch>:REMote:INITialization:FILE
on page 933
:SCONfiguration:EXTernal:IQOutput<ch>:REMote:INITialization:FILE
on page 933
:SCONfiguration:EXTernal:RF<ch>:REMote:INITialization:FILE
on page 933
Remove Initialization Sequence
Deletes the loaded sequence.
Apply
Confirms the settings and displays the external instrument in the "External RF and I/Q"
dialog.
Remote command:
:SCONfiguration:EXTernal:CODer<ch>:REMote:ISELect on page 931
:SCONfiguration:EXTernal:FADer<ch>:REMote:ISELect on page 931
:SCONfiguration:EXTernal:BBMM<ch>:REMote:ISELect on page 931
:SCONfiguration:EXTernal:IQOutput<ch>:REMote:ISELect on page 931
:SCONfiguration:EXTernal:RF<ch>:REMote:ISELect on page 931
System Configuration Settings