Signal Routing and System Configuration
R&S
®
SMW200A
193User Manual 1175.6632.02 ─ 30
To define the baseband signal
To generate an EUTRA/LTE signal, use the following general steps:
1. Select "Baseband > EUTRA/LTE".
2. Configure the settings as required.
For example, enable "EUTRA/LTE > Link Direction > Downlink".
Select a "DL Test Model > E-TM1.1 5MHz"
3. Select "EUTRA/LTE > State > On" to enable signal generation.
4. In the status bar, select "Frequency A = Frequency B = 2.1432 GHz" and "Lev A =
Lev B = -60 dBm".
5. Select "RF A > On" and "RF B > On".
4.9.4
How to Route the I/Q Streams to the Output Interfaces
This example shows how to enable the instrument to output the EUTRA/LTE 1x4x4
MIMO signal at both RF outputs and both I/Q analog outputs.
1. Select "Block Diagram > I/Q Stream Mapper".
2. In the stream to connector mapping matrix, tap on a crossing cell to enable the
routing of the selected stream to the corresponding connector.
For example, enable "Stream A > RF A", "Stream B > RF B", "Stream C > I/Q OUT
1" and "Stream D > I/Q OUT 2".
How to Connect External Instruments and Configure the Signal Flow