Configuring the Internal Baseband Source
R&S
®
SMW200A
257User Manual 1175.6632.02 ─ 30
Settings:
Marker Mode...............................................................................................................257
Marker x Delay............................................................................................................257
Marker Mode
Basic marker configuration for up to three marker channels. The contents of the dialog
change with the selected marker mode.
Use the settings to define the shape and periodicity of the markers. See Chap-
ter 5.5.1.2, "Regular Marker Output Signals", on page 231 for description of the regular
marker signals.
The instrument routes the generated marker signals to the selected output connectors.
See also Chapter 12.2, "Configuring Local and Global Connectors", on page 714.
"CList"
A marker signal as defined in the selected control list.
Remote command:
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:MODE on page 1010
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PULSe:DIVider on page 1011
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PULSe:FREQuency?
on page 1011
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PATTern on page 1010
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:OFFTime on page 1010
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:ONTime on page 1010
ARB: see "Marker Mode" on page 311
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:MODE on page 1086
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PULSe:DIVider on page 1087
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PULSe:FREQuency?
on page 1087
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PATTern on page 1086
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:ONTime on page 1086
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:OFFTime on page 1086
Marker x Delay
Delays the marker signal at the marker output relative to the signal generation start.
Variation of the parameter "Marker x Delay" causes signal recalculation.
Common Functions and Settings in the Baseband Domain