Configuring the Internal Baseband Source
R&S
®
SMW200A
268User Manual 1175.6632.02 ─ 30
"Pattern"
Use the "Pattern" box to define a bit pattern with a maximum length of
64 bits.
Remote command:
[:SOURce<hw>]:BB:DM:PATTern on page 993
"Data List"
Binary data from data lists are used, see Select Data List.
Remote command:
[:SOURce<hw>]:BB:DM:DLISt:CATalog? on page 1012
complete[:SOURce<hw>]:BB:DM:DLISt:SELect on page 1013
"External"
An externally supplied serial data is used, see "External Modulation
Data" on page 226.
Data and clock signals are expected at the corresponding connec-
tors.
Remote command:
[:SOURce<hw>]:BB:DM:SOURce on page 993
Select Data List
Accesses the standard "Select List" dialog to select an existing data list or to create a
new one.
Data lists can be generated externally or internally in the data editor.
●
Select the "Select Data List > navigate to the list file *.dm_iqd > Select" to select an
existing data list.
●
Use the standard "File Manager" function to transfer external data lists to the
instrument.
●
Use the "New" and "Edit" functions to create internally new data list or to edit an
existing one, see Chapter 5.6.3.7, "Data List Editor", on page 279.
See also Chapter 5.6.4.2, "How to Create and Assign a Data List", on page 287
Remote command:
[:SOURce<hw>]:BB:DM:DLISt:CATalog? on page 1012
complete[:SOURce<hw>]:BB:DM:DLISt:SELect on page 1013
[:SOURce<hw>]:BB:DM:DLISt:COPY on page 1016
[:SOURce<hw>]:BB:DM:DLISt:DELete on page 1014
Select Control List
Accesses the standard "Select List" dialog to select an existing control list or to create
a new one.
Control lists can be generated externally or internally in the "Control and Marker Lists"
editor.
●
Select the "Select Control List > navigate to the list file *.dm_iqc > Select" to select
an existing control list.
●
Use the standard "File Manager" function to transfer external lists to the instrument.
●
Use the "New" and "Edit" functions to create internally new list or to edit an existing
one, see Chapter 5.6.3.8, "Control and Marker Lists Editor", on page 281.
Irrespectively on the way they are created, control lists are not automatically used (see
"How to assign and activate control signals from a control list" on page 287).
Generating Custom Digital Modulated Signals