EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - Page 287

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the Internal Baseband Source
R&S
®
SMW200A
287User Manual 1175.6632.02 ─ 30
The created file is an ASCII file with the extension *.dm_iqc
Enable the instrument to use the control list, e.g. for the marker and/or other con-
trol signals.
Enabled control signals are indicated as active in the "Configure Control Signal"
section.
How to assign and activate control signals from a control list
Irrespectively on the way they are created, generated control lists are not automatically
used.
To use a marker/control signal from a control list and to output this signal at the suppor-
ted connector, perform the following:
1. Enable the R&S SMW to use the control list for marker output 2.
Output this signal at the T/M2 connector:
a) Select "Baseband > Custom Digital Modulation > Marker > Marker 2 Mode >
CList".
b) Select "Baseband > Custom Digital Modulation > Marker > Local Connector
Setting".
Select "T/M 2 > Direction = Output", "T/M 2 > Signal = Baseband A Marker 2".
2. To enable the R&S SMW to use the "Burst Gate" and "Level Attenuation" control
signals as defined in a control list and output one of them at the T/M3 connector:
a) Select "Baseband > Custom Digital Modulation > Power Ramp Control >
Source > Internal"
b) Select "Baseband > Custom Digital Modulation > Marker > Local Connector
Setting".
Select "T/M 3 > Direction = Output", "T/M 3 > Signal = Lev Att A".
5.6.4.2 How to Create and Assign a Data List
The R&S SMW provides the following ways to create a data list file:
To use the dedicated Data List Editor and create a file with extension *.dm_iqd,
see "To create data lists manually" on page 287
To use the tag-oriented format and create a data list file, see "To create a data list
file using tag file format" on page 326.
To use SCPI commands and create a file in binary format, see "To create a data list
in binary format" on page 326.
To create data lists manually
Use the intuitive build in Data List Editor dialog:
1. To access the "Data List Editor":
a) Select "Baseband > Custom Digital Mod > Data Source > Data List"
b) Select "Select Data List"
Generating Custom Digital Modulated Signals

Table of Contents