Configuring the Internal Baseband Source
R&S
®
SMW200A
362User Manual 1175.6632.02 ─ 30
Multi Segment Table
The table lists the individual waveforms (segments) of the selected multi-segment
waveform. The information about the segments is retrieved from the tags of the corre-
sponding waveform files.
"Segment#"
Indication of segment index. Within the manual and remote control
configuration, this segment index indicates the segment explicitly.
Tip: Use the segment index, for example, to define the subsequent
sequence to be output in Next Segment Mode "Next Segment" or
"Next Segment Seamless".
"Waveform"
Indication of the waveform filename of the segment.
"Clock Rate"
Indication of the clock rate of the selected waveform.
"Samples"
Indication of the number of samples in the segment.
"Period"
Indication of the segment duration.
"Path"
Indication of the location of the waveform file used for the corre-
sponding segment.
"Comment"
Indication of the possible comment contained in the waveform.
"Info"
Indication of the possible comment contained in the waveform.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SEGMent:CATalog?
on page 1040
Append/Delete/Shift Seg. Up/Down
Standard handling functions:
"Append"
Opens the standard "File Select" dialog for navigation to and selec-
tion of the waveform file to be added on the end of the existing list.
Only non-multi segment waveforms can be loaded.
"Delete"
Removes the selected entry from the table. The waveform file itself is
however not deleted.
"Shift Seg.# Up/Down"
Rearranges the segments, i.e. moves the selected segment up and
down.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SEGMent:APPend
on page 1045
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:DELete on page 1045
Blank Segment
Comprises the settings of a blank segment. A blank segment is a zero signal with
defined clock rate and number of samples.
Generating Multi-Segment Waveform Files