Configuring the RF Signal
R&S
®
SMW200A
465User Manual 1175.6632.02 ─ 30
The Minimal Frequency and Maximal Frequency parameters show the actual fre-
quency range the specific R&S SZU100A provides.
Note: The performance in the extended range can deviate from the specified values
given in the data sheet of the R&S SZU100A.
Note: Preset behavior.
The impact of an instrument preset depends on the "Preset behavior: keep connec-
tions to external instruments" setting in the connection configuration:
●
Enabled
The setting is not affected by an instrument preset ([PRESET] key or *RST) and
the "Save/Recall" function. It is reset only by factory preset.
●
Disabled
The instrument preset also deactivates the frequency overrange.
See Chapter 4.4.3.1, "Connections Configuration and Connection Status Overview
Settings", on page 136
Remote command:
[:SOURce<hw>]:FREQuency:CONVerter:EXTernal:OVERrange[:STATe]
on page 1135
Minimal Frequency ← Frequency Overrange
Displays the minimum frequency value of the connected R&S SZU100A.
Remote command:
[:SOURce<hw>]:FREQuency:CONVerter:EXTernal:OVERrange:FREQuency:
MIN? on page 1135
Maximal Frequency ← Frequency Overrange
Displays the upper frequency value of the connected R&S SZU100A.
Remote command:
[:SOURce<hw>]:FREQuency:CONVerter:EXTernal:OVERrange:FREQuency:
MAX? on page 1134
User Variation
Defines and activates a user-defined step width for varying the RF frequency or RF
level with the rotary knob.
If disabled, the step width varies in steps of one unit at the cursor position.
Variation Active ← User Variation
Activates the set user-defined step width.
Remote command:
[:SOURce<hw>]:FREQuency:STEP:MODE on page 1132
[:SOURce<hw>]:POWer:STEP:MODE on page 1195
Variation Step ← User Variation
Sets the user-defined step width.
Remote command:
[:SOURce<hw>]:FREQuency:STEP[:INCRement] on page 1133
[:SOURce<hw>]:POWer:STEP[:INCRement] on page 1196
Configuring RF Frequency and Level