EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - Page 467

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the RF Signal
R&S
®
SMW200A
467User Manual 1175.6632.02 ─ 30
Setting Characteristics................................................................................................ 468
Level Range................................................................................................................469
Readjust......................................................................................................................470
Limit.............................................................................................................................470
Offset...........................................................................................................................470
User Variation..............................................................................................................470
Variation Active............................................................................................. 470
Variation Step................................................................................................471
RF State/RF ON
Activates or deactivates the RF output.
Acts as the [RF ON/OFF] key.
Remote command:
:OUTPut<hw>[:STATe] on page 886
:OUTPut:ALL[:STATe] on page 885
Amplitude
Sets the level of the RF signal.
The value is offset-free and corresponds to the level at the RF A/RF B connector.
See Chapter 8.4.4.1, "Displayed RF Frequency and Level Values with Downstream
Instruments", on page 472.
Note: Suppressed values in the status bar
For security concerns or certain operating modes, you can hide the frequency and
level display in the status bar.
The display has been disabled for security reasons.
See:
Annotation Frequency
Annotation Amplitude
The display is disabled when:
List mode is running, see Chapter 8.7, "Varying the RF Signal in List or Sweep
Mode", on page 491.
Digital only signals are generated, see the user manual "R&S SMW-K551 Gen-
eration of Digital "Slow IQ" Signals"
Remote command:
[:SOURce<hw>]:POWer:POWer on page 1195
Note: The SCPI command [:SOURce<hw>]:POWer[:LEVel][:IMMediate][:
AMPLitude] sets the level of the "Level" display.
This means, the level containing offset.
Digital Attenuation
Attenuates or raises the level of the internal, digitally modulated I/Q baseband signals,
and thus the level of the RF signal accordingly.
Configuring RF Frequency and Level