Loading...
Configuring the RF Signal
R&S
®
SMW200A
518User Manual 1175.6632.02 ─ 30
The remote commands required to define these settings are described in Chap-
ter 14.19.12, "SOURce:LIST Subsystem", on page 1164.
General Settings................................................................................................... 518
List Mode Data Settings........................................................................................521
Import/Export Settings...........................................................................................522
8.7.6.1 General Settings
Access:
Select "RF" > "Sweep/List" > "List mode > General".
In the "General" tab, you can configure the trigger and dwell time modes for list
processing and activate signal generation.
Settings
State............................................................................................................................518
Current Index.............................................................................................................. 519
Mode........................................................................................................................... 519
Dwell Time Mode.........................................................................................................519
Global Dwell Time....................................................................................................... 519
Run Mode....................................................................................................................520
Learn List Mode Data..................................................................................................520
Trigger Slope...............................................................................................................520
Show Connector..........................................................................................................520
Reset...........................................................................................................................520
Execute Single............................................................................................................ 520
State
Activates the list mode and processes the currently selected list.
Note: Active RF frequency, RF level or RF combined sweep modes deactivate the LF
sweep or List mode and vice versa.
Remote command:
[:SOURce<hw>]:FREQuency:MODE on page 1128
Varying the RF Signal in List or Sweep Mode