Configuring the RF Signal
R&S
®
SMW200A
547User Manual 1175.6632.02 ─ 30
Remote command:
[:SOURce<hw>]:AM:DEViation:MODE on page 968
Total Depth ← AM settings
Sets the sum of the signal Depth for path 1 and path 2 in per cent when using com-
bined sources and Deviation Mode > Fixed Total.
Provided both signal paths are turned on, the depth of both paths always sum up to the
value of the total depth.
Behavior when changing any depth settings:
Changing the total depth adjusts the depths of both paths proportionally.
Changing the depth of one path adjusts the depth of the other path. The sum
always results in the set total depth.
Remote command:
[:SOURce<hw>]:AM:DEPTh:SUM on page 968
Ratio Path2/Path1 ← AM settings
Sets the deviaton ratio of the signal depth for path 2 to path 1 in per cent when using
combined sources.
Remote command:
[:SOURce<hw>]:AM:RATio on page 969
8.8.4.3 Pulse Generator Settings
Access:
Select "RF > Analog Modulation > Pulse Generator".
The "Pulse Generator" tab contains the settings for creating the pulse modulation
signal internally.
Analog Modulations