Configuring the RF Signal
R&S
®
SMW200A
548User Manual 1175.6632.02 ─ 30
Pulse Generator > General Settings
Access:
► Select "RF" > "Analog Modulation" > "Pulse Generator".
Settings
Pulse Mode................................................................................................................. 548
Trigger Mode...............................................................................................................548
Pulse Period................................................................................................................550
Pulse Width.................................................................................................................550
Double Pulse Width.....................................................................................................550
Pulse Delay.................................................................................................................551
Double Pulse Delay.....................................................................................................551
Pulse Output State......................................................................................................551
Pulse Output Polarity.................................................................................................. 551
Set Global Connector for Pulse Modulation................................................................551
Pulse Mode
Sets the operating mode of the pulse generator. Depending on the selection, the instru-
ment displays the associated parameters.
"Single"
Generates a single pulse in one pulse period.
"Double"
Generates two pulses in one pulse period.
Remote command:
[:SOURce<hw>]:PULM:MODE on page 980
Trigger Mode
Selects between continuous triggering or triggering initiated by a trigger event from an
external signal.
"Auto"
Generates the internal modulation signal continuously.
"Ext Single"
Generates a single pulse signal, triggered by an external signal.