Configuring the RF Signal
R&S
®
SMW200A
549User Manual 1175.6632.02 ─ 30
"Ext Triggered"
Generates the pulse signal each time an external trigger event
occurs.
Example: Generation of double pulse signal ("Pulse Mode = Dou-
ble") using "Trigger Mode = Ext Triggered"
1 = External trigger signal input with "Trigger Input Polarity = Normal" (the positive
slope is active)
2 = Sync signal
3 = Pulse signal
a = Trigger signal during double pulse generation is without effect
Δt = Trigger delay between the trigger and the sync signal start; see data sheet
delay = "Double Pulse Delay = 200 ns"; the first pulse starts without a delay
PW = "Double Pulse Width = 100 ns"
Analog Modulations