Configuring the RF Signal
R&S
®
SMW200A
589User Manual 1175.6632.02 ─ 30
The remote commands required to define these settings are described in Chap-
ter 14.17, "SENSe, READ, INITiate and SLISt Subsystems", on page 888, includ-
ing the triggering of the measurement and the retrieval of measurement results.
Settings:
Sensor type and serial number................................................................................... 589
Level (Peak) / Level (Average)....................................................................................589
Sensor Mapping..........................................................................................................589
Sensor Settings...........................................................................................................590
State..............................................................................................................590
Zero...............................................................................................................590
Display.......................................................................................................... 590
Permanent.......................................................................................... 590
Display................................................................................................590
Use Frequency Of.........................................................................................590
Frequency.....................................................................................................591
Level Offset State,Level Offset..................................................................... 591
Filter..............................................................................................................591
Filter Length..................................................................................................592
Auto Once.....................................................................................................592
Noise/Signal Ratio........................................................................................ 592
Timeout......................................................................................................... 592
Default Aperture Time...................................................................................592
Aperture Time............................................................................................... 592
S-Parameter..................................................................................................593
Enable Logging.............................................................................................593
Sensor type and serial number
Indicates the type and the serial number of the selected R&S NRP power sensor, and
the channel the sensor is assigned to.
The displayed Level (Peak) / Level (Average) values correspond to the particular sen-
sor.
Remote command:
:SENSe<ch>[:POWer]:TYPE? on page 903
:SENSe<ch>[:POWer]:SNUMber? on page 901
Level (Peak) / Level (Average)
Indicates the measured peak or average level value.
You can also change the unit for the results display: Watt, dBm or dBμV.
Note: Peak level measurements are provided if the power sensor supports this feature.
Remote command:
:READ<ch>[:POWer]? on page 895
:SENSe<ch>:UNIT[:POWer] on page 895
Sensor Mapping
Accesses the NRP Sensor Mapping dialog.
Improving Level Performance