EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - How to Recall User Settings Automatically after Preset; Reference

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
File and Data Management
R&S
®
SMW200A
677User Manual 1175.6632.02 ─ 30
2. Select "Mark all parameters changed from preset".
If enabled, the corresponding settings are marked.
Example:
Figure 11-2: Labeled parameters show that the value deviates from its default
Frequency = changed (default = 1 GHz)
Offset = changed (default = 0 kHz)
Multiplier = unchanged
Variation active = changed (default = disabled)
Variation step = unchanged
11.2.3 How to Recall User Settings Automatically after Preset
You can define the settings that are restored when you preset the instrument.
1. Configure the settings as required. Save them as described in Chapter 11.4.2,
"How to Save and Recall Instrument Settings", on page 684.
2. Save the settings as a file with the predefined filename UserPreset.savrcltxt.
Save this file in the directory /var/user/.
The filename UserPreset.savrcltxt and the directory /var/user/ are man-
datory.
Now when you press the [PRESET] key or send the *RST command to the instru-
ment, the defined settings are restored.
An "Info" message appears and confirms, that a file with user-defined preset set-
ting is loaded.
11.2.4 Reference
See Table 11-1 for an overview of the main generator settings that are affected by the
corresponding preset functions. While the regular [PRESET] key primarily resets the
Restoring the (Default) Instrument Configuration