File and Data Management
R&S
®
SMW200A
698User Manual 1175.6632.02 ─ 30
The default password is 123456. For more information, refer to Chapter 12.6,
"Using the Security Settings", on page 752.
5. Select "Accept".
To enable file transfer via USB
1. Select "System Config > Setup > Security > Security > General"
2. Enable "USB Storage"
3. Enter the "Security Password".
The default password is 123456. For more information, refer to Chapter 12.6,
"Using the Security Settings", on page 752.
4. Select "Accept".
11.9.2 Accessing the File System of the R&S SMW via ftp
If the R&S SMW is connected to a LAN, you can use file transfer protocol (ftp) to
access the file system and to transfer files from and to the instrument.
How to: see Chapter 13.6.3, "How To Connect to LAN", on page 804.
To access the file system via ftp
We assume that the instrument and the remote PC are connected to a LAN.
1. Enable file transfer via ftp
2. Enable write permission on the file system
3. On the remote PC, start the Windows Explorer.
4. In the address field, enter ftp://<"IP Address" of the Instrument>, e.g.
ftp://10.124.0.166.
Tip: The R&S SMW indicates its IP address on the block diagram.
A log-on dialog opens and requests a password.
The default user name and password is instrument.
Tip:
Default password
The FTP and SAMBA file access use the user "instrument" with default password
"instrument".
We recommend that you change this password in the "Setup > Security > Pass-
word Management > Change User Password" dialog before connecting the instru-
ment to the network.
See Chapter 12.6.4, "Password Management", on page 762.
5. Enter the password to access the user directory.
The user directory corresponds to the /var/user/ directory of the instrument.