General Instrument Functions
R&S
®
SMW200A
718User Manual 1175.6632.02 ─ 30
Option: R&S SMW-B9
Table 12-4: Control signals mapped to T/M/C connectors (System Configuration > BB Sources = Sep-
arate/Coupled per Entity)
Connector
shared between
"Baseband
A/C"
Connector
shared between
"Baseband B/D"
Direction Assigned Signal
T/M/C 1 T/M/C 3 Output
"Symbol Clock <BB>"
2)
"Baseband <BB> Marker 1/2"
T/M 2 T/M 4 Output "Baseband <BB> Marker 1/2"
2)
where:
●
<BB> = A/C or B/D
in "System Configuration > Baseband
Source > Separate"
●
<BB> = 1/3 or 2/4
in "System Configuration > Baseband
Source > Coupled per Entity"
T/M 2 T/M 4 Input "Feedback"
Table 12-5: Control signals mapped to T/M/C connectors (System Configuration > BB Sources = Cou-
pled)
Connector Direction Assigned Signal
T/M/C 1 Output "Symbol Clock"
"Baseband Marker 1"
T/M 2 Output "Baseband Marker 2"
T/M 2 Input "Feedback"
T/M/C 3 Output "Symbol Clock"
T/M 4 Input "Data"
"Feedback"
12.2.2.3 Trigger Marker Clock and RF Connectors
The Trigger Marker Clock Settings and RF Connectors Settings dialogs provide an
overview of the current mapping of the logical signals to the corresponding connectors.
The dialogs are summary representation of related settings, as configured with the
Global Connectors Settings and Local Connectors Settings settings.
12.2.2.4 Status Indicators
Connector status LEDs
A dedicated LED indicates the connector status:
●
green: an input connector
●
yellow: an output connector
●
no light / gray: the connector is not active
Configuring Local and Global Connectors