General Instrument Functions
R&S
®
SMW200A
727User Manual 1175.6632.02 ─ 30
"REG trigger A/B"
Automatically generated output signal used for latency calibration in
the Radar Echo Generation (REG) mode.
See user manual R&S SMW-K78 Radar Echo Generation.
"Baseband Sync Out/Baseband Sync In"
Option: R&S SMW-B9
Signals available in enabled primary-secondary instrument mode.
●
"Baseband Sync Out"
One or more outputs of a dedicated synchronization (and trigger)
signal, that has to be fed into the secondary instruments.
●
"Baseband Sync In"
In the secondary instruments, at most one input for the synchroni-
zation (and trigger) signal.
Can be assigned to any global connector.
See also Chapter 10.3.1, "Connecting Multiple Instruments in Pri-
mary-Secondary Instrument Mode", on page 640.
"Always 0/Always 1"
Control signal with low or high level.
"Manual Trigger"
Output of a short pulse signal that can serve as a common external
trigger signal for triggering of several R&S SMW.
See Example "Triggering several R&S SMW instruments simultane-
ously" on page 649.
"BER Data", "BER Clock", "BER Data Enable", "BER Restart"
Option: R&S SMW-K80
Input signals for BERT/BLER testing.
See user manual R&S SMW-K80 Bit Error Rate Tester.
"BER TestGen Data" , "BER TestGen Clock", "BER TestGen Data Enable", "BER Test-
Gen Restart"
Option: R&S SMW-K80
Output signals for BERT/BLER testing.
See user manual R&S SMW-K80 Bit Error Rate Tester.
"External
Restart REG
Trigger A/B"
Option: R&S SMW-K78
External restart trigger signals for radar echo generator (REG).
See user manual R&S SMW-K78 Radar Echo Generation.
"None"
No signal is assigned to the connector.
Remote command:
[:SOURce]:INPut:USER<ch>:SIGNal on page 949
:OUTPut:USER<ch>:SIGNal on page 950
Execute Trigger
If "User 6 > Direction = Output" and "Signal = Manual Trigger", generates a short pulse
signal and outputs it at the USER 6 connector.
Configuring Local and Global Connectors