EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - How to Enable Signals and Perform Signal to Connector Mapping

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General Instrument Functions
R&S
®
SMW200A
731User Manual 1175.6632.02 ─ 30
Threshold Clock/Trigger Input
Sets the high/low threshold in volts for the trigger and clock signal inputs of the base-
band section.
Remote command:
[:SOURce<hw>]:INPut:TM:CLOCk:LEVel on page 952
[:SOURce<hw>]:INPut:TM:TRIGger:LEVel on page 952
Impedance Clock/Trigger Input
Selects the input impedance for the external trigger/clock inputs.
Remote command:
[:SOURce<hw>]:INPut:TM:CLOCk:IMPedance on page 953
[:SOURce<hw>]:INPut:TM:TRIGger:IMPedance on page 953
Clock Input Slope
Sets the polarity of the active slope of an externally applied clock signal.
Custom digital modulation with external serial data (Data Source > "External"): A
higher bit modulation extern serial data requires a reference symbol clock signal to
generate a bit clock out of it.
This parameter sets the active edge of the symbol clock.
To set the active edge of the bit clock, use the parameter Bit Clock Slope.
Observe the impact of this parameter on the preview graphic in the "Baseband >
Custom Digital Mod > Data Source" dialog.
See also "External Modulation Data" on page 226.
Remote command:
[:SOURce<hw>]:INPut:TM:CLOCk:SLOPe on page 953
Trigger Input Slope
Sets the polarity of the active slope of an externally applied trigger signal.
Remote command:
[:SOURce<hw>]:INPut:TM:TRIGger:SLOPe on page 954
12.2.7 How to Enable Signals and Perform Signal to Connector Mapping
This section introduces the general principle of connector configuration.
General Workflow
The Figure 12-2 shows the main configuration stages, together with the corresponding
user interface dialogs.
Configuring Local and Global Connectors

Table of Contents