Loading...
Network Operation and Remote Control
R&S
®
SMW200A
796User Manual 1175.6632.02 ─ 30
The "LXI - Status" dialog shows the parameters of the LAN connection.
Alternatively, you can change the LAN settings using the LXI web browser interface,
see Chapter 13.5.2.1, "LAN Configuration", on page 798.
LAN Status
The LED indicates the LXI status.
"green"
Normal operation
"green (flashing)"
Device identification
"red"
LAN fault
Hostname / MAC Address / IP Address
See "Hostname" on page 786.
LAN Reset
Initiates the network configuration reset mechanism for the instrument and resets the
hostname, MAC address, and IP address.
According to the LXI standard, a LAN reset must place the following network settings
to a default state:
Parameter Value
TCP/IP mode DHCP + Auto IP address
Dynamic DNS Enabled
ICMP ping Enabled
Password for LAN configuration LxiWebIfc
The LAN reset also resets the following parameters for the R&S SMW:
LXI Settings

Table of Contents