Remote Control Commands
R&S
®
SMW200A
873User Manual 1175.6632.02 ─ 30
DIAGnostic:HUMS:DEVice:HISTory:DELete:ALL
This command deletes the complete device history information of the connected instru-
ment.
Example: //Delete complete device history
DIAG:HUMS:DEV:HIST:DEL:ALL
Usage: Event
Manual operation: See "Delete History" on page 794
DIAGnostic:HUMS:FORMat <DataFormat>
This command defines the format for the queried HUMS data. You can query the
HUMS data either in JSON format or XML format.
The defined format affects all other commands that return block data.
Parameters:
<DataFormat> JSON | XML
JSON
Returns the HUMS data in JSON format.
XML
Returns the HUMS data in XML format.
*RST: JSON
Example: //Return data in JSON format
DIAG:HUMS:FORM JSON
DIAGnostic:HUMS:SAVE
This command saves the HUMS history as a ZIP file to your preferred path.
Example:
//Save HUMS history data
DIAG:HUMS:SAVE 'C:\HUMS\hums_2021.zip'
Usage: Event
Manual operation: See "Export History" on page 794
DIAGnostic:HUMS:STATe <State>
This command turns the HUMS service and data collection on and off.
Parameters:
<State> ON | OFF | 1 | 0
*RST: ON
Example: //Turn on HUMS service
DIAG:HUMS:STAT ON
Manual operation: See "State" on page 794