:SCONfiguration:RFALignment:SETup:INFO:CALibration:AGE?
Queries how many days are passed since the moment the calibration described in the
loaded setup file is performed.
Return values:
<Days> integer
Time since calibration in days
Example: See Example "Retrieving details on the calibrated values"
on page 935.
Usage: Query only
Manual operation: See "Time since Last Calibration" on page 657
:SCONfiguration:RFALignment:SETup:INFO:CALibration:TEMPerature:OFFSet?
Queries the difference in temperature since the moment the calibration described in
the loaded setup file is performed.
Return values:
<TempOffset> float
Increment: 0.01
Example: See Example "Retrieving details on the calibrated values"
on page 935.
Usage: Query only
Manual operation: See "Temperature Offset to Last Calibration" on page 657
:SCONfiguration:RFALignment:SETup:INFO:CALibration:PARameters?
Queries information on the major calibrated parameters.
Return values:
<CalibratedParam> string
Example: See Example "Retrieving details on the calibrated values"
on page 935.
Usage: Query only
Manual operation: See "Calibrated Parameters" on page 656
:SCONfiguration:RFALignment:SETup:INFO:CALibration:FREQuency:MODE?
:SCONfiguration:RFALignment:SETup:INFO:CALibration:POWer:MODE?
Queries the method used to defined the calibrated frequency and PEP ranges.
Return values:
<Mode> RANGe | LIST