Remote Control Commands
R&S
®
SMW200A
945User Manual 1175.6632.02 ─ 30
SOURce:LIST Subsystem...................................................................................1164
SOURce:NOISe Subsystem................................................................................1179
SOURce:PGEN Subsystem................................................................................ 1186
SOURce:PHASe Subsystem...............................................................................1187
SOURce:POWer Subsystem...............................................................................1188
SOURce:ROSCillator Subsystem....................................................................... 1198
RF Ports Alignment.............................................................................................1203
SOURce:SWEep Subsystem..............................................................................1205
14.19.1 Connector Settings
This section summarizes the commands of the OUTPut and INPut subsystems, nec-
essary to configure the connectors settings. Listed are the commands for configuring
the output signals and the inputs for trigger, data, and control signals.
The ...:USER<ch>:... commands determine the global trigger threshold and input
impedance values, that affect all trigger and control signal inputs. The connector set-
tings concern to all digital modulations, the generation of waveforms or multi carrier
signals, and all digital standards.
The settings affect both paths.
Refer to Chapter 14.19.8, "SOURce:INPut Subsystem", on page 1135 for description
of the commands for configuring the inputs for external modulation signals.
Required options
See also Chapter 12.2, "Configuring Local and Global Connectors", on page 714.
Example: Global connectors settings configuration
SOURce1:INPut:USER1:DIRection INP
SOURce1:INPut:USER1:SIGNal TRIG1
SOURce1:INPut:USER3:DIRection INP
SOURce1:INPut:USER3:SIGNal NSEGM1
SOURce1:INPut:USER4:DIRection INP
SOURce1:INPut:USER4:SIGNal IPULSA
SOURce1:INPut:USER5:DIRection INP
SOURce1:INPut:USER5:SIGNal TRIG2
SOURce1:INPut:USER:TRIGger:LEVel 1.5
SOURce1:INPut:USER:PULM:LEVel 2
// the signal threshold at USER 1-3 is 1.5 V
// this applies to all input signal, i.e. TRIG1 and NSEGM1
// the signal threshold at USER 4-6 is 2 V
// this applies to all input signal, i.e. IPULSA and TRIG2
SOURce1:INPut:USER1:TRIGger:IMPedance G1K
SOURce1:INPut:USER1:TRIGger:SLOPe POS