Remote Control Commands
R&S
®
SMW200A
981User Manual 1175.6632.02 ─ 30
Example: See Example "Perform pulse modulation" on page 979.
Manual operation: See "Pulse Mode" on page 548
[:SOURce<hw>]:PULM:TRIGger:MODE <Mode>
Selects a trigger mode - auto, external, external single or external gated - for generat-
ing the modulation signal.
Parameters:
<Mode> AUTO | EXTernal | EGATe | ESINgle
*RST: AUTO
Example: See Example "Perform pulse modulation" on page 979.
Manual operation: See "Trigger Mode" on page 548
[:SOURce<hw>]:PULM:PERiod
<Period>
Sets the period of the generated pulse, that means the repetition frequency of the inter-
nally generated modulation signal.
Parameters:
<Period> float
The minimum value depends on the installed options
R&S SMW-K22 or R&S SMW-K23
Range: 20E-9 to 100
Increment: 5E-9
*RST: 10E-6
Example: See Example "Perform pulse modulation" on page 979.
Manual operation: See "Pulse Period" on page 550
[:SOURce<hw>]:PULM:WIDTh <Width>
Sets the width of the generated pulse, that means the pulse length. It must be at least
20ns less than the set pulse period.
Parameters:
<Width> float
Range: 20E-9 to 100
Increment: 10E-9
*RST: 2E-6
Example: See Example "Perform pulse modulation" on page 979.
Manual operation: See "Pulse Width" on page 550
[:SOURce<hw>]:PULM:DELay <Delay>
Sets the pulse delay.
SOURce Subsystem