1222User Manual 1178.6462.02 ─ 29
Example:
:CONTrol1:RFFE1:TEST:DATA:RANGe 20.0mA
:CONTrol1:RFFE1:TEST:CLOCk:RANGe 2mA
:CONTrol1:RFFE1:TEST:VIO:RANGe 0.2mA
:CONTrol1:RFFE1:TEST:DATA:SHUNt?
Returns 10 [Ω]
:CONTrol1:RFFE1:TEST:VIO:RANGe 2mA
:CONTrol:RFFE1:TEST:CLOCk:SHUNt?
Returns 100 [Ω]
:CONTrol1:RFFE1:TEST:VIO:RANGe 0.2mA
:CONTrol:RFFE1:TEST:VIO:SHUNt?
Returns 1000 [Ω]
Usage: Query only
Options: R&S ZN-B15/Z15 Var. 03
Manual operation: See "Range / Shunt" on page 661
2 μA 20 μA 200 μA 2 mA 20 mA
Shunt 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ
CONTrol:RFFE<Bus>:TEST:CLOCk:VOLTage?
CONTrol:RFFE<Bus>:TEST:DATA:VOLTage?
CONTrol:RFFE<Bus>:TEST:VIO:VOLTage?
Returns the results of the voltage measurement on the related RFFE pin.
Suffix:
<Bus>
.
RFFE bus interface 1 or 2
Return values:
<Measured> Measured voltage
Usage: Query only
Options: R&S ZN-B15 Var. 03
Manual operation: See "Voltage, Current" on page 662
CONTrol<Ch>:RFFE:TEST:OUTPut
Applies the current output voltage and current range (shunt) settings to the RFFE/
GPIO pins.
Same function as CONTrol<Ch>:GPIO:VOLTage:OUTPut.
Suffix:
<Ch>
.
Channel number
Usage: Event
Options: R&S ZN-B15/Z15 Var. 03
Manual operation: See "Set" on page 662