EasyManua.ls Logo

Rohde & Schwarz R&S ZNA Series - Page 756

Rohde & Schwarz R&S ZNA Series
1849 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GUI reference
R&S
®
ZNA
756User Manual 1178.6462.02 ─ 29
Remote command:
n.a.
Output Directory...
Opens a dialog that allows you to specify the directory where the fixture modeling tools
store their data.
Default is
C:\Users\Public\Documents\Rohde-Schwarz\ZNA\Embedding.
Remote command:
CALCulate:FMODel:DIRectory
CALCulate:FMODel:DIRectory:DEFault
CALCulate:FMODel:DIRectory:DEFault:CLEar
Deembedding Files...
This button is only enabled, if the coupon data provided to the deembedding tool was
at least partly loaded from file. See "Page 2: Measure / Load and Apply" on page 761.
A section "Coupon B" is only available, if you uncheck "Use Same Coupon Left and
Right" on page 760 and specify a file instead of measuring "Coupon B".
Remote command:
CALCulate:FMODel:DEASsistant:COUPon:LEFT:FILE
CALCulate:FMODel:DEASsistant:COUPon:RIGHt:FILE
All Deembedding Activated
Deactivates or activates all deembeddings (single-ended, balanced, port set, ground
loop) for the active channel, if any.
Offset Embed softtool

Table of Contents

Related product manuals