701User Manual 1173.9163.02 ─ 53
"RF Connections" is enabled if at least one switch matrix is configured.
Optimization
Allows you to select between different switch matrix routing optimizations:
"Speed" – switch as little as possible
"Precision" – always use the best possible route in terms of quality ("priority")
See Chapter 5.7.22.4, "Multiple Paths: Precision vs. Speed", on page 245 for back-
ground information.
The selection is only enabled, if at least one of the connected switch matrices has mul-
tiple routes with non-identical priorities.
6.17.5.2 Define Physical Ports Dialog
Allows you to redefine the physical VNA ports (see Chapter 5.3.1.2, "Redefined S-
Parameters", on page 117).
Access: SYSTEM – [SETUP] > "External Ports" > "Define Ports..."
Redefining physical ports causes a factory reset.
The factory reset deletes all switch matrix RF connections.
a wave, b wave, Source
Define a physical port by assigning its reference receiver, measurement receiver and
generator, respectively.
Remote command:
[SENSe:]UDSParams<Pt>:PARam
[SENSe:]UDSParams:ACTive
6.17.5.3 External Matrices Dialog
The "External Matrices" dialog allows you to discover and register external switch
matrices.
Access: SYSTEM – [SETUP] > "External Ports" > "Switch Matrix..."
Background information
Refer to section Chapter 5.7.22, "External Switch Matrices", on page 241.