EasyManua.ls Logo

Rohde & Schwarz R&S ZVA 8 - Page 245

Rohde & Schwarz R&S ZVA 8
813 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R&S
®
ZVA/ZVB/ZVT Trace Menu
1145.1084.12 4.83 E-6
Freq Re(S11) Im(S11) Re(S21) Im(S21) Re(S12) Im(S12) Re(S22) Im(S22)
(all values arranged in 1 line)
3-port files (*.s3p)
Freq Re(S11) Im(S11) Re(S12) Im(S12) Re(S13) Im(S13)
Re(S21) Im(S21) Re(S22) Im(S22) Re(S23) Im(S23)
Re(S31) Im(S31) Re(S32) Im(S32) Re(S33) Im(S33)
(values arranged in 3 lines)
4-port files (*.s4p)
Freq Re(S11) Im(S11) Re(S12) Im(S12) Re(S13) Im(S13) Re(S14) Im(S14)
Re(S21) Im(S21) Re(S22) Im(S22) Re(S23) Im(S23) Re(S24) Im(S24)
Re(S31) Im(S31) Re(S32) Im(S32) Re(S33) Im(S33) Re(S34) Im(S34)
Re(S41) Im(S41) Re(S42) Im(S42) Re(S43) Im(S43) Re(S44) Im(S44)
(values arranged in 4 lines)
The stimulus frequencies are arranged in ascending order. If a lin. Mag-Phase (MA) or dB Mag-Phase
(DB) data format is selected the real and imaginary S-parameter values Re(S
ij
), Im(S
ij
) are replaced by
lin Mag(S
ij
), phase(S
ij
) or dB Mag(S
ij
), phase(S
ij
), respectively.
ASCII (*.csv) files
An ASCII file contains a header and the actual trace data:
freq;reTrc1_S21;imTrc1_S21;reMem2[Trc1]_S21;imMem2[Trc1]_S21;
300000.000000;0.000000;0.000000;0.000000;0.000000;
40499497.487437;0.000000;0.000000;0.000000;0.000000;
80698994.974874;0.494927;-0.065174;0.500833;-0.074866;
120898492.462312;0.497959;-0.111724;0.488029;-0.107375;
...
The header consists of the following data elements:
<Stimulus> stimulus variable: freq for Frequency sweep, power for Power sweep, time for Time
sweep, trigger for CW Mode sweep.
<reTrace1> first response value of first trace: re<Trace_Name>, mag<Trace_Name> or
db<Trace_Name> for output format Re/Im, lin. Mag-Phase or dB Mag-Phase, respectively. The data
format for export files can be selected in the Export Data dialog.
<imTrace1>
<reTrace2>
<imTrace2>... second response value of second trace. first response value of second trace.
HZ / KHZ / MHZ / GHZ allowed for imported files. The analyzer alway uses HZ for exported
data. second response value of first trace: im<Trace_Name> for output format Re/Im,
ang<Trace_Name> for output formats lin. Mag-Phase or dB Mag-Phase. The data format for export
files can be selected in the Export Data dialog.
The trace data is arranged as described in the header. Different values are separated by semicolons. A
semicolon is also inserted before the end of each line.
The stimulus values are arranged in ascending order.

Table of Contents