Remote control commands
R&S
®
RTA4000
686User Manual 1335.7898.02 ─ 08
Parameters:
<AddressMinimum> 01X-string
TRIGger:A:MILStd:SADDress:CONDition <Compare>
For the subaddress, sets the triggering condition for the comparison of the decoded
value to the defined range.
Parameters:
<Compare> EQUal | NEQual | GTHan | GEQual | LEQual | LTHan | WITHin |
OUTSide
*RST: OFF
TRIGger:A:MILStd:SADDress:MAXimum
<AddressMaximum>
Sets the maximum subaddress.
Parameters:
<AddressMaximum> 01X-string
TRIGger:A:MILStd:SADDress:MCADdress <ModeCodeAddress>
Triggers on the value of the subaddress, if TRIGger:A:MILStd:COMMand:TYPE is
set to MCODE.
Parameters:
<ModeCodeAddress> A0 | A31 | EITHer
*RST: EITH
TRIGger:A:MILStd:SADDress:MINimum <AddressMinimum>
Sets the minimum subaddress.
Parameters:
<AddressMinimum> 01X-string
TRIGger:A:MILStd:STATus:BCReceived <StatusBit>
Triggers on the state of the broadcast command received bit of the status word.
Parameters:
<StatusBit> 0 | 1 | X
*RST: X
TRIGger:A:MILStd:STATus:BUSY <StatusBit>
Triggers on the state of the busy bit of the status word.