Fernsteuerbefehle
R&S
®
RTB2000
305Bedienhandbuch 1333.1611.03 ─ 05
REFCurve<m>:SOURce.................................................................................................305
REFCurve<m>:SOURce:CATalog?.................................................................................. 305
REFCurve<m>:STATe.....................................................................................................306
REFCurve<m>:UPDate.................................................................................................. 306
REFCurve<m>:SAVE..................................................................................................... 306
REFCurve<m>:LOAD.....................................................................................................306
REFCurve<m>:LOAD:STATe...........................................................................................307
REFCurve<m>:HORizontal:POSition................................................................................307
REFCurve<m>:HORizontal:SCALe..................................................................................307
REFCurve<m>:VERTical:POSition...................................................................................307
REFCurve<m>:VERTical:SCALe..................................................................................... 307
REFCurve<m>:WCOLor................................................................................................. 308
REFCurve<m>:LABel..................................................................................................... 308
REFCurve<m>:SOURce <Source>
Defines the source of the reference waveform.
Suffix:
<m>
.
1..4
Selects the reference waveform
Parameter:
<Source> CH1 | CH2 | CH3 | CH4 | QMA | RE1 | RE2 | RE3 | RE4 | D70 |
D158 | SPEC | MINH | MAXH | AVER
CH1 | CH2 | CH3 | CH4 | QMA | RE1 | RE2 | RE3 | RE4
Any active channel, math, or reference waveform. CH3 and CH4
are only available with 4-channel R&S RTB2000 oscilloscopes.
D70 | D158
Logic probes, sources require MSO option R&S RTB-B1.
SPEC | MINH | MAXH | AVER
FFT waveforms: spectrum, min hold, max hold, average.
*RST: CH1
REFCurve<m>:SOURce:CATalog?
Returns the source waveform.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameter:
<Source Catalogue> CH1 | CH2 | CH3 | CH4 | QMA | RE1 | RE2 | RE3 | RE4 | D70 |
D158 | SPEC | MINH | MAXH | AVER
See REFCurve<m>:SOURce auf Seite 305.