Fernsteuerbefehle
R&S
®
RTB2000
307Bedienhandbuch 1333.1611.03 ─ 05
REFCurve<m>:LOAD:STATe
Loads the instrument settings in addition to the reference waveform data. The wave-
form data must be loaded before the settings, see REFCurve<m>:LOAD auf Seite 306.
The settings are only available if the file was stored to the internal storage and never
written to a USB flash device.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Verwendung: Ereignis
REFCurve<m>:HORizontal:POSition
<Position>
Changes the horizontal position of the reference waveform independently of the chan-
nel waveform settings.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameter:
<Position> Std.-einheit: s
REFCurve<m>:HORizontal:SCALe <Scale>
Changes the horizontal scale (timebase) of the reference waveform independently of
the channel waveform settings.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameter:
<Scale> Std.-einheit: s/div
REFCurve<m>:VERTical:POSition <Position>
Changes the vertical position of the reference waveform.
Suffix:
<m>
.
1..4
Selects the reference waveform.
Parameter:
<Position> Std.-einheit: div
REFCurve<m>:VERTical:SCALe <Scale>
Changes the vertical scale of the reference waveform.