Fernsteuerbefehle
R&S
®
RTB2000
317Bedienhandbuch 1333.1611.03 ─ 05
Parameter:
<Width> Bereich: Depends on various settings, mainly time base and
sample rate
*RST: 400e-6
Std.-einheit: s
SEARch:TRIGger:RUNT:DELTa <DeltaWidth>
Sets a range Δt to the reference pulse width set with SEARch:TRIGger:RUNT:WIDTh
, if SEARch:TRIGger:RUNT:RANGe is set to WITHin or OUTSide.
Parameter:
<DeltaWidth> Bereich: Depends on various settings, mainly time base and
sample rate
*RST: 100e-6
Std.-einheit: s
15.6.4.7 Konfiguration Daten-zu-Takt-Suche
SEARch:TRIGger:DATatoclock:CSOurce..........................................................................317
SEARch:TRIGger:DATatoclock:CLEVel............................................................................ 317
SEARch:TRIGger:DATatoclock:DLEVel............................................................................ 317
SEARch:TRIGger:DATatoclock:CLEVel:DELTa..................................................................318
SEARch:TRIGger:DATatoclock:DLEVel:DELTa..................................................................318
SEARch:TRIGger:DATatoclock:CEDGe............................................................................318
SEARch:TRIGger:DATatoclock:HTIMe............................................................................. 318
SEARch:TRIGger:DATatoclock:STIMe..............................................................................318
SEARch:TRIGger:DATatoclock:CSOurce <ClockSource>
Selects the input channel of the clock signal.
Parameter:
<ClockSource> CH1 | CH2 | CH3 | CH4
*RST: CH1
SEARch:TRIGger:DATatoclock:CLEVel <ClockLevel>
Sets the voltage level for the clock signal. The crossing of clock level and clock edge
defines the start point for setup and hold time.
Parameter:
<ClockLevel> Bereich: Depends on vertical scale
SEARch:TRIGger:DATatoclock:DLEVel <DataLevel>
Sets the voltage level for the data signal. The data lavel defines the threshold for data
transition.
Messkurvenanalyse